Choose a Solid State Relay for This Controller:
|
Crydom
D2W202F
SPST-NO
|
 |
2A 240VAC Normally Open SPST
Zero Crossing Turn On
Built-In Snubber Circuit
For Use with Resistive Loads
AC Switching ONLY
.06A Minimum Load Required
-30 to 80°C Operating Temperature
D2W Series Data Sheet |
$23.61/each |
Crydom
CX240D5
SPST-NO
|
 |
5A 240VAC Normally Open SPST
Random Turn On
For Use with Resistive Loads
AC Switching ONLY
.06A Minimum Load Required
-30 to 80°C Operating Temperature
CX Series Data Sheet
|
$18.68/each |
Crydom
CX240D5R
SPST-NO
|
 |
5A 240VAC Normally Open SPST
Random Turn On
For Use with Inductive Loads
AC Switching ONLY
.06A Minimum Load Required
-30 to 80°C Operating Temperature
CX Series Data Sheet
|
$19.79/each |
Crydom
PF240D25R
SPST-NO
|
 |
25A 240VAC Normally Open SPST
Random Turn On
For Use with Inductive Loads
AC Switching ONLY
.06A Minimum Load Required
-30 to 80°C Operating Temperature
PF Series Data Sheet |
$35.19/each |
Crydom
PF480D25
SPST-NO
|
 |
25A 480VAC Normally Open SPST
Zero Crossing Turn On
For Use with Resistive Loads
AC Switching ONLY
.06A Minimum Load Required
-30 to 80°C Operating Temperature
PF Series Data Sheet |
$37.98/each |
Crydom
MPDCD3
SPST-NO
|
 |
3A 60VDC Normally Open SPST
For Use with Resistive or Inductive Loads
DC Switching ONLY
.02A Minimum Load Required
1.5V Maximum On-State Voltage Drop
-40 to 80°C Operating Temperature
PF Series Data Sheet
DC Solid State Connection Diagram |
$29.88/each |
TYPE H
Crydom
CMX60D10
SPST-NO
|
 |
10A 60VDC Normally Open SPST
For Use with Resistive or Inductive Loads
DC Switching ONLY
No Minimum Load Required
.1V Maximum On-State Voltage Drop
-30 to 80°C Operating Temperature
CX Series Data Sheet |
$48.30/each |
TYPE G - 45 Day Lead Time
Crydom
CMX60D20
SPST-NO
|
 |
20A 60VDC Normally Open SPST
For Use with Resistive or Inductive Loads
DC Switching ONLY
No Minimum Load Required
.1V Maximum On-State Voltage Drop
-30 to 80°C Operating Temperature
CX Series Data Sheet
|
$79.57/each |
NOTICE: Solid State Relays are Silent and Offer Extremely Long Life, but May Not Function Properly when Subjected to Radioactive Environments. Forced Air May be Required to Achieve Maximum Load Rating. NCD does NOT Recommend Driving any Relay at Maximum Load. It is Not Possible for NCD to verify Manufacturer Claims of Load Ratings. NCD Solid State Relay Controllers have NOT been Tested at the Rated Loads. Solid State Relays must be carefully selected, AC and DC solid state relays cannot be used interchangeably. Solid State Relays Require a Minimum Load, and will NOT Function Correctly Unless Minimum Load Requirements are Met. External Snubber Circuitry May be Required for Certain Applications. If a Device Turns On, but Does Not Turn Off, this Usually Indicates a Need for a External Snubber Circuit. This May Indicate Minimum Load Requirements Have Not Been Met. Please Research Crydom Solid State Relays or be Familiar with this Technology Prior to Purchase. Please Consult Crydom Engineers to Determine the Best Relay for Your Application www.crydom.com. |