Wired Contact Closure Relay 2-Channel 5-Amp
MIRXR25_ZRS
Wired Contact Closure Relay
The MirXR25_ZRS Wired Contact Closure Relay is a set of two boards with one contact closure input and one relay. The Contact closure input controls the relay on the opposite board through a 3-wire connection. A simple dry contact closure will connect to the input of one of the boards and control a corresponding relay over a wired connection no more that 1000' (300 meters). Contact closure input such as buttons, relays, switches or other electronic devices (no voltage) attached to inputs on either board will control the relay on the opposite board.MirXR25_ZRS The Ideal Choice
The MirXR25_ZRS Wired Contact Closure Relay is an ideal choice for wired contact closure switching. The wired connection provides a secure way to communicate between boards.
Wired Contact Closure Relay 2-Channel 5-Amp
MIRXR25_ZRSWired Contact Closure Relay
- 2 5-Amp Relay Installed
- Single Pole Double Throw (SPDT) Relay
- Temperature Rating -40° C to 85° C - Each Device Controls the Other Device
- 2 Contact Closure Input on Each Board
- 2 5-Amp Relay on Each Board
- Input Controls Relay on Opposite Board
- Sold in Pairs - Wired Operation Up to 1000'
- Using 3-Wire Cable - Works Together Right Out of the Box!
- No Computer, No Programming, Just Wire it Up!
Wired Range
Each board is equipped with a ZRS Module. The ZRS Modules will be physically wired together using the screw terminal located on the module. A Quality cable such a s twisted pair Cat 5 or Cat 6 is ideal with a working range of 1000 feet between controllers.
MirX Wired
Wired Contact Closure
The MIRXR25_ZRS are sold in pairs, you will receive both boards shown here when you purchase this set. These boards will give you the opportunity to control a relay using a simple dry contact. Contact closure devices such as buttons and switches attached to inputs on either board will control relays on the opposite board. Both boards are basically the same except the inputs will always control the relays on the other board. When an input on one board is tripped by a contact closure the corresponding relay on the other board is energized. Communication between both boards through a wired connection. Pricing shown on our web site indicates pricing for the pair of boards.Go Where Wireless Won't Reach
MirX boards with a wired connection should be used in applications where wireless is not an option. Direct wired applications are advisable between thick masonry walls, steel, or underground installations where a wireless signal won't travel or in areas where there may be interference. MirX_ZRS controllers are also suitable in applications where security may be a concern.ZRS Modules
Each board is equipped with a ZRS Module. The ZRS Modules will be physically wired together using the screw terminal located on the module. A Quality cable such a s twisted pair Cat 5 or Cat 6 is ideal with a working range of 1000 feet (300 meters) between controllers. The module is powered from the board and each board will require 12 volts of power and can be hard wired or you can purchase a "wall wart" type Power Supply at checkout.
Read Status of Remote Relays
Both boards are also equipped with LEDs that display the status of the remote relay. Status information is verified using 2-way wireless communications. If communication is lost between the devices, the LED will turn off. Additionally, every MirX controller is equipped with a Busy/Ready LED. If the Busy LED flashes, this indicates the other device has successfully received and accepted your contact closure status. If the Busy LED does not flash, the remote device is out of range (1000' or 300 m).
- Order of Operations
- Contact closures are read on one controller
- Data is sent to other controller to turn on or off relays
- Remote device replies back
- Busy light flashes to confirm data was received at the other end
What Happens When Communication is Lost
A common question we receive is what happens to the relay that is energized and communication between the boards is lost. The relay can remain energized or on until communication is re-established or the relay can de-energize or turn off. This is done by a simple jumper on the board and setting it to Beacon or Smart mode. Regardless of the Mode you choose, if the busy LED flashes, the two devices are communicating properly. If the Busy LED does not flash at all, the devices are unable to communicate.Dry Contact Input ONLY
Please Note: Users must NEVER apply any voltage to an input on the MirX Boards, these inputs are for
Dry Contact Connections ONLY.
MirX Board Features
MirX Relay
This pair of boards allows you to control a relay using a dry contact (no voltage). The dry contact can come from a manual switch, a sensor or device that provides a contact closure, or another relay. As long as the contact closure circuit is closed the relay will remain energized or on. When the circuit opens the relay will de-energize or turn off. Meaning the relay will respond to a toggle or momentary connection depending on what type of input you select. Each MirC pair is ready to stand up to rigorous demands from heat, cold or vibration. Take it from us, these controllers will hold up!Status of Remote Relays
Both boards are also equipped with LEDs that display the status of the remote relay. Status information is verified using 2-way wireless communications. If communication is lost between the devices, the LED will turn off. Additionally, every MirX controller is equipped with a Busy/Ready LED. If the Busy LED flashes, this indicates the other device has successfully received and accepted your contact closure status. If the Busy LED does not flash, the remote device is out of range.
Contact Closure Inputs
The inputs on these boards accept a dry contact only - no voltage. Users must never apply any voltage to an input on either of the MirX Controllers.Relay Outputs
Relays do NOT provide a voltage output and can be used as a dry contact. They provide a contact closure output and simply interrupt the power to the device you are switching. The relays are rated for 240 VAC or 24 VDC. See the Data Sheets tab above for the specs on relays installed.SPDT Relay Installed
This device has SPDT relays installed. SPDT Single Pole Double Throw Relays have three connections - Common, Normally Open, and Normally Closed. When the relay is off, the common is connected to the normally closed connection of the relay. When the relay coil is energized, the Common swings to the Normally Open Connection of the Relay. You can wire the device you are switching to either the Normally Open or the Normally Closed position using screw terminal connections. The maximum guage wire the terminal can handle is 14 ga but we have used up to 12 ga solid core for several applications with no issues.
2-Million Cycles
MirX series controllers are designed for long life, you should expect to get years of service from your controller and literally 2-million cycles from the relays on board. With a 5-year warranty and a money back guarantee you have nothing to loose! Place your order now, while everything is in front of you.Break-A-Way Tabs for a Smaller Design
The MirX relays have a great feature where space is a premium - Break-A-Way Tabs. The Break-A-Way Tabs allow most boards to fit in an optional undrilled plastic enclosure. Snap off the Break-A-Way Tabs and you have a controller with a smaller profile when you need to fit in a tight space.
5-Year Warranty/Money Back Guarantee
MirX controllers are guaranteed against manufacturing and functionality defects for a full 5 years! Not to mention a 30-day money back guarantee! If for any reason you are not happy with a relay purchased from Relay Pros, simply return it within 30 days and we will give you your money back! Controllers that are damaged by our customers will not of course be warranted under any circumstances.This Board is RoHS Compliant
This board is led free and RoHS Compliant. If your requirements are for RoHS compliant parts this board is manufactured with RoHS compliant led free parts and solder.
Shipping
The boards sold are brand new units shipped from our office conveniently located in Missouri. These boards are completely tested before they are released for shipping With so many boards on our site it is impossible to stock boards, please allow two to three days production time for your order to ship. If you have any questions please feel free to call our office at 800-960-4287 or e-mail us at sales@relaypros.com.Contact Closure Relay Is Here!
A more streamlined manufacturing process brings a more durable, reliable and better relay board to the market. Here's a lists of great features:- Single Pole Double Throw Relays Installed
- Wire to Normally Open or Normally Closed Position
- 12 Guage Solid Core Wire Capacity - Screw Terminal Contact Closure and Relay Connections
- Break-A-Way Tabs Lets you Decide the Board's Size
- Temperature Rating -40° C to 85° C
- RoHS Compliant
User Friendly Board Design
- Control Relay From a Dry Contact (No Voltage)
- Inputs and Relays on Both Boards
- Inputs Control Relays on Opposite Board
- Each Board Displays Status of Remote Relays
MirX Features
Building a Power Budget
The operating range of the board is between 9 & 14 VDC, any power outside this range and the board can become unreliable. Use the tables below to build a power budget for the board you have based on the module you have and the anticipated time the relay will be active.
Power & More
SPDT Relay Controller Specifications
This table covers all NCD SPDT Relay Controllers. All ratings assume 12VDC operation at 70°F (21°C). Please note that most ratings are estimated and may be subject to periodic revision. Some ratings represent stock controller settings without performance enhancement optimizations. The estimated processing time can be impacted by background services and choice of commands. Standby power consumption assume no communications module is installed and no relays are active on the controller. Please add the power consumption of the activated relays and communications module to obtain a better estimation of power consumption.| Specs of NCD SPDT Relay Boards | Minimum | Nominal | Maximum | Notes |
| Operational Voltages | 10VDC | 12VDC | 15VDC | |
| Standby Power Consumption | 35mA | 100mA | 200mA | No Active Relays, No Com Module |
| Relay Power Consumption | 28mA | 35mA | 60mA | Consumption of Each Activated Relay |
| Operational Temperature Range | -40°F (-40°C) | 70°F (21°C) | 185°F (85°C) | Theoretical Component Limits Shown |
| Storage Temperature Range | -67°F (-55°C) | 70°F (21°C) | 185°F (85°C) |
Theoretical Component Limits Shown |
| Operational Ambient Air Humidity | 0% | 50% | 70% | Non-Condensing Humidity Values Shown |
| Relay Activation Time | 4ms | 5ms | 10ms | Needs Further Validation |
| Relay Deactivation Time | 5mS | 10mS | 15mS | Needs Further Validation |
SPDT Relay Installed
This device has SPDT relays installed. SPDT Single Pole Double Throw Relays have three connections - Common, Normally Open, and Normally Closed. When the relay is off, the common is connected to the normally closed connection of the relay. When the relay coil is energized, the Common swings to the Normally Open Connection of the Relay. You can wire the device you are switching to either the Normally Open or the Normally Closed position using screw terminal connections. The maximum guage wire the terminal can handle is 14 ga but we have used up to 12 ga solid core for several applications with no issues.
2-Million Cycles
ProXR series controllers are designed for long life, you should expect to get years of service from your controller and literally 2-million cycles from the relays on board. With a 5-year warranty and a money back guarantee you have nothing to loose! Place your order now, while everything is in front of you.Communication Module Specifications
This table covers all NCD Communication Modules. While NCD communication modules operate at 3.3VDC, the ratings below highlight the effect they will have on the master controller operating at 12VDC at 70°F (21°C). Maximum ratings should be used for power budget planning purposes and may reflect short term absolute maximum peak current consumption. Some ratings are estimated and subject to periodic revision.| Specs of NCD Communication Modules | Minimum | Nominal | Maximum | Notes |
| Operational Temperature Range | -40°F (-40°C) | 70°F (21°C) | 185°F (85°C) | Theoretical Component Limits Shown |
| Storage Temperature Range | -67°F (-55°C) | 70°F (21°C) | 185°F (85°C) | Theoretical Component Limits Shown |
| Operational Ambient Air Humidity | 0% | 50% | 70% | Non-Condensing Humidity Values Shown |
| USB Module Power Consumption | N/A | N/A | N/A |
USB Modules are Powered by the USB Port Do Not Consume Device Current |
| RS-232 Module Power Consumption | 10mA | 20mA |
|
|
| Ethernet Module Power Consumption | 58mA | 82mA | 100mA | |
| WiFi Bluetooth USB Module Power Consumption | 37mA | 50mA | 100mA | Up to 300 Foot Indoor Wireless Range, Unobstructed. Up to 50 Foot Range Through Walls |
| 900MHz Wireless Module Power Consumption | 13mA | 30mA | 50mA | Up to 1,000 Foot Indoor Wireless Range, up to 2 Mile Outdoor Wireless Range using Included Antennas. Up to 28 Miles Outdoor Wireless Range using High-Gain Antennas. |
| KFX Wireless Key Fob | 11mA | 15mA | 25mA | Up to 200 Feet Outdoor Wireless Range using 1, 2, 3, 4, or 5 Button Key Fobs. Up to 700 Feet Outdoor Wireless Range using 8-Button Remotes |
AD8 Analog Input Usage Notice
Analog Inputs should not have a voltage present when powered down. Use a 220 Ohm current limiting resistor on each input to prevent damage to the controller if voltage will be present on the analog input when this controller is powered down. Do not exceed 0 to 5VDC on any analog input or the on-board CPU will be damaged. Most analog inputs include a 10K Pull Up/Down resistor to help keep the inputs quiet when not in use. This 10K resistor may slightly bias the readings of some sensors.Accessories
Power Supply Available
Reliable Power MeansReliable Switching
The PWR12 is regulated power supply providing clean power necessary for the performance of these boards. The PWR12 US power supply is a 120VAC to 12VDC 1.25A 60Hz regulated power supply and it plugs into the barrel connector on the board. The output connector is a 2.1mm I.D. x 5.5mm O.D. x 9.5mm R/A barrel connector.
Enclosure Available
The SFL Enclosure is an undrilled, non-waterproof enclosure and is available at checkout. Each board is the same dimensions and fit the same enslosure.SFL Spec Sheet
CAD Drawing: SFL CAD Drawing
3D Model: SFL_3D
Induction Suppression
Controlling
an inductive load using our relay controllers requires the use of induction suppression capacitors. The purpose of this capacitor
is to absorb the high voltages generated by inductive loads, blocking them from the contacts of the relay. Without this capacitor,
the lifespan of the relay will be greatly reduced. Induction can be so severe that it electrically interferes with the microprocessor
logic of our controllers, causing relay banks to shut themselves down unexpectedly.
What Is Relay Logic?
Relay logic uses relays wired in specific configurations to achieve predictable switching behavior. In practical terms, it's the process of arranging relays so they perform the logical control functions your application requires.
Get a printout of this page
Relay Logic
Relay Wiring Samples
This page provides simple examples showing how to wire a single relay - or multiple relays - for common switching applications. We use a light as the example load, but you can substitute a gate controller, security panel input, dry contact device, motor trigger, or most other switched loads. These wiring samples demonstrate different ways to connect relays to achieve the switching behavior you need.
SPDT Wiring
SPDT (Single Pole Double Throw) relays include three terminals: Common (COM), Normally Open (NO), and Normally Closed (NC).
- When the relay is off, COM is connected to NC.
- When the relay is energized, COM switches to NO.
Your load can be wired to either the NO or NC terminal depending on whether you want the device to turn on when the relay activates or when it releases. Examples below demonstrate both wiring methods.
SPST Wiring
SPST (Single Pole Single Throw) relays provide two terminals: Common (COM) and Normally Open (NO).
When the relay coil is energized, COM connects to NO to power the load. The only SPST relays offered on this site are our 30-Amp models. All SPST examples shown on this page apply to these relays as long as the example does not require a Normally Closed terminal.
DPDT Wiring
A DPDT (Double Pole Double Throw) relay contains two SPDT switches that operate together.
- Each side includes its own COM, NO, and NC terminals.
- Both internal switches change state at the same time.
This allows you to control two independent circuits with one relay. Wiring for each side of a DPDT relay follows the same rules as an SPDT relay, so the examples on this page apply directly.
Relay Logic Examples
Example 1 - Simple Off/On Control
This example shows the most basic way to use a relay to switch a device such as a light. When the relay energizes, its NO (Normally Open) contact closes to COM (Common), completing the circuit and turning the light on.Only a single power wire is switched in this setup, making it the simplest method for controlling a light - or any device - using a relay.
Use this example for switching a light or any device you want to power only when the relay is on.
Example 2 - Simple On/Off (Using NC Contact)
This wiring method keeps the device on by default. The relay switches a single power wire through the COM (Common) and NC (Normally Closed) terminals.When the relay is not energized, the NC contact is closed to COM and the light remains on.
When the relay energizes, the NC contact opens, interrupting power and turning the light off.
This approach is ideal for devices that stay on most of the time, reducing relay wear since it doesn't need to remain energized to keep the device powered. It's also a useful method for power-cycling equipment - energizing the relay momentarily will turn the device off.
Example 3 - AND Logic Using Two Relays
This example shows how two relays can work together so a light turns on only when both relays are energized. This creates an AND Logic condition:Relay 1 AND Relay 2 must be on for the light to receive power.
A single power wire is switched, but it must pass through both relay contacts before reaching the light. This setup is ideal when two conditions must be met at the same time - such as requiring input from multiple sensors or system parameters.
MirC/MirX Users: This wiring requires two contact closure inputs on the sender board before the receiver's relay activates. Use this approach when two independent outputs must close before turning on the light.
- For example, a light could turn on only when:
- A light sensor detects it's dark AND
- A motion sensor detects activity in the room
Example 4 - AND Logic Using Three Relays
This example expands on the previous AND Logic concept. Here, the light will turn on only when all three relays are energized:
Relay 1 AND Relay 2 AND Relay 3 must be on for power to reach the light.
A single power wire is routed through all three relay contacts. Wiring from the NO (Normally Open) of Relay 1 to the COM (Common) of Relay 2, then from the NO of Relay 2 to the COM of Relay 3, creates a series path that requires every relay to close before the light can activate.
This method can be scaled easily - just continue wiring NO of each relay to the COM of the next relay. Add as many relays as needed to meet your logic or safety requirements.
Example 5 - Override Function
This example demonstrates the and/or function. The light bulb will be activated if Relay 1 and Relay 2 are energized OR if Relay 3 is energized. This example is great for applications that may require a logical condition of 2 relays plus an override feature. For instance, if Relay 1 is a night/day sensor, Relay 2 is a moisture sensor. If its dark and the soil is dry, Relays 1 and 2 can activate a pump. If you want to override these conditions with local physical switch using Relay Activator function (see the AD8 Command Set Tab) Relay 3 would override Relays 1 & 2.
MirC/MirX Users: Add a manual button or switch to control the third relay to manually control the light if you have sensors that control the other relays.
Reactor Users: Add a manual button or switch to control the third relay to manually control the light if you have sensors that control the other relays.
Example 6 - Either Relay Activates
This example demonstrates how either relay can be used to activate a light. Only one power wire is switched in this example using either of two relays to turn on the light. In this sample, only one activated relay is required to activate the light. If both relays are activated, the light will be on. Great for if you have a timer for one of the relays but want to turn the light on when the timer is scheduled off or have two sensors connected and want either of them to control a device. MirC/MirX Users: Two contact closure inputs in the sender board and either of the inputs can control one light or device.
Example 7 - 3-Way Switch
This example demonstrates how to create a 3-way light switch to activate a light. A 3-way light switch is where two light switches can be used to activate a single light. This sample is exactly the same as a 3-way light switch, the only difference being each physical switch is replaced by a relay. Operationally, it works the same way. Only one power wire is switched in this example using both relays to turn on the light. Each relay activation will cause the light to toggle. Switching two relays at one time is like flipping 2 switches at once....with the same result. This sample is particularly useful since you can replace one relay (as shown in the diagram) with a physical light switch. This will allow a computer to control a light as well as manual operation of a light. Properly used, this can be one of the most valuable diagrams we offer on this page.
Example 8 - Motor Control
This example demonstrates how to control the direction of a DC motor using 2 relays. Braking is accomplished by connecting both motor terminals to a common power connection (Faraday's Law). The capacitors shown may not be required for small motors, but if you experience problems with relays shutting themselves off, the induction suppression capacitor will be required. The .1uF capacitor helps suppress electronic noise if the battery were to be used by sensitive devices (such as radios/amplifiers).
- Relay 1 Off Relay 2 Off = Motor Brake to +
- Relay 1 On Relay 2 Off = Motor Forward
- Relay 1 Off Relay 2 On = Motor Backward
- Relay 1 On Relay 2 On = Motor Brake to -
- Induction Capacitor Should Be located by relay
- Filter Capacitor Should be Located Near Motor
- Additional Capacitors May be Desirable for Some Motors